Automated maintenance and control of alkalinity!
The maintenance of alkalinity is the most important aspect for maintaining a reefs, stability is the key. If you are looking to achieve exceptional coral growth conditions, Kh Director a must!
Thanks to the KH Director, watch, hold and control alkalinity with ease.
How does KH Director® work?
Le KH Director ® est conçu pour fonctionner avec un GHL Doser 2 (2.2) Standalone ou un ProfiLux® Aquarium Controller 3 ou 4 avec un Doser 2 Slave pour le fonctionnement.
Les 2 entrées et 1 sortie du KH Director se connectent à 3 pompes de dosage sur le Doser 2 (2.2). Ces 3 pompes sont alors responsables du transfert précis du fluide vers et depuis le directeur du KH.
A sample of the aquarium water is first sent to the KH Director®. Then, the value of KH is precisely determined by slowly adding another liquid (reactive) and by measuring the value of the pH.
The water sample is then pumped again and collected in a separate container for subsequent elimination.
What are the costs for the reagent and pH electrode?
At GHL, we understand the importance of permanent costs related to automated KH supervision and control. For the director of KH, it was particularly important to take these costs into account and develop a very effective and profitable product. A single reagent bottle of 1000 ml can last up to 3 months when the test is carried out 4 times a day at a KH value of 8. The PH electrode used by the director KH has been specially designed for KH measurement and has an average lifespan of 1 to 2 years.
Configuration options
KH DIROSE ® can be used in two ways:
1. Le KH Director ® est connecté au GHL Doser 2 (2.2) SA via le ProfiLux Aquatic Bus (PAB).
2. The KH DIRECTOR® is connected to profile 4 and to a Slave GHL DOSER 2 (2.1) via the Aquatic Bus profile (PAB).
Kh Director® - Characteristics
Laboratory quality KH measurement precision
Measure your alkalinity with laboratory accuracy. With only a 100 ml water sample, Kh Director® can provide measurement values with a precision of 0.1 ° DKH.
Test sample volume adjustable by the user
In practice, a precision of 0.1 ° DKH is not always necessary. For this, the volume of test sample can be reduced. A precision of approx. 0.2 ° DKH can still be obtained with a smaller water sample.
Measures per adjustable day
If the KH value does not fluctuate sharply, the number of measures can be reduced.
Greater precision and security provided by additional valves
Test your alkalinity with confidence and consistency. The integrated valves guarantee exactly the same measurement conditions and prevent the sample liquid from reflected in the aquarium, even in the improbable case of a defect.
Economic and safe reactive fluid
Each test requires only 1 - 3 ml per measure.
Automated data recording
Examine the results of the past tests, determine the sudden KH changes and refine your KH dose with the help of automatic data recording.
Automated liquid supply
Automatic food for KH-BOOSTING liquids.
* Fourth dosage pump required
LED state display
The GHL LED L -embedded OGO practices in a color state code indicators. The bright colors show you the condition of your system at a glance .
- White = configuration mode
- Blue = normal operation
- Green = a quantity of liquid in a liquid container is ok
- Yellow = w Warning threshold - Fluid containers are low
- Red = alarm threshold - the liquid reservoirs are empty
Myghl Cloud accessible
Access the KHD via the MyGHL® cloud service via GHL Dosser2 / GHL DOSER 2.1 or Profession 3 / Profile 3.1 / profile 4 .
Transparent integration with GHL system
Grâce à l’utilisation de la connexion PAB ( ProfiLux Aquatic Bus ), KH Director® s’intègre parfaitement dans le système modulaire d’aquarium GHL . La connexion PAB assure une communication sans interférence avec d’autres appareils GHL PAB tels que le GHL Doser 2.2 ou le ProfiLux® 4.
Low maintenance design
The unique design of the KH DIROSE Facilitates the access and maintenance of the include pH electrode. Calibration and replacement, easy .
KH value display
Visualize your KH statement as soon as you wish, via the profile screen, the Touch profiles or the web browser (MyGHL®), an optional external screen as an optional external screen .
Robust design built in laboratory quality
Each product we manufacture is designed to last. The KH Director® is no exception. In the smallest detail, the KH Director® is built of sustainable materials and meets the requirements of the laboratories.
Technical specifications:
Kh Director® is available in two colors: black or white
Dimensions (mm) : 220 x 150 x 70 mm ( without pH electrode )
Kh Director® includes the following elements:
- Device with integrated measurement cell
- PH electrode, specially designed for KHD, included. calibration liquids
- Reactive test 500 ml
- Silicone hose
- Power distributor cable
Avis
Il n’y a pas encore d’avis.